Rhinoman Fitment Instructions for Utility Drawer

Fitment Instructions

for Rhinoman

Utility Unit

Drawers

XTREME, XPEDITION & RHINOLITE

Fitment Kit Contents

Description
Quantity
Illustration
A. Utility drawer unit
1
B. M6 x 16 Socket button head screw
2
C. M6 x 20 Socket button head screw
2
D. M6 Flat washer
6
E. M6 Nyloc nut
2

Required Tools

Description
Illustration
1 x 4mm Allen Key
1 x 8mm Spanner (Optional when replacing pop rivets with M5 fasteners)
1 x 8mm Socket (Optional when replacing pop rivets with M5 fasteners)

Installation Time & Care Instructions

⚠︎ Be aware of the edges on all sheet metal components and take extra care during handling.
⚠︎ Ensure that the area where the table hanger will be installed is free from any obstructions.
  • Torque all M6 fasteners to 10.5Nm.

Fitment Steps

Step 1
  • 50% Utilities only accommodates for a fitment in the center of the utility.
  • 100% utilities accommodates a fitment of either left-or-right hand side of the utility.
  • Familiarize yourself with the fastening points, to ensure that the correct pre-cut hole positions in the utility will be utilized. Fig. 2.2.1
  • Locate the correct pre-cut holes, then remove the press out pieces.
Step 2
  • Prior to placing the drawer unit into the utility unit, open the bottom shelf completely to access fastening point A, insert 1 x M6x16 and 1 x M6 Flat washer in both fastening point A’s as indicated in Fig. 2.3.1
  • Place the drawer unit into the utility unit, with the pre-fit M6 screws locating into the utility’s fastening point A. Fig. 2.3.2
  • From the outside of the utility’s rear panel, insert 1 x M6 x 20 button head screw and 1 x M6 flat washer into both fastening point B’s. Fig. 2.3.3
  • Returning to fastening points A, secure both M6 x 16 button head screws with 1 x M6 Flat washer and 1 x M6 nyloc nut each. Fig. 2.3.4
Step 3
  • Repeat step 2 for multiple drawer unit installations.
  • Multiple drawers can only be installed in a 100% utility unit.
Step 4
  • You have now successfully completed the assembly and fitment of your Rhinoman utility drawer.
  • Confirm that all the fitment screws have been properly tightened one last time.
  • Be sure to check at least bi-monthly that all the screws are still properly tightened.
Should you have any enquiries about the fitment, feel free to contact us